Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud

Verified by manufacturer 2 days ago

K10 127 2 x 12.5 mm Wallboard

Protektor Group UK Variant:

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud.

Jump to:
01562 515200 Website

Application

  • Suitable for use where fire and acoustic performance is required.
  • Suitable for use in large commercial spaces.

Description

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud.

Features and benefits:

  • Sever duty rating to BS 5234.
  • Sound insulation (Rw dB): up to 53 dB Rw.
  • Available with or without acoustic partition roll.

General information

Color

Other

Finish

Other

Material

Plasterboard

Metal

Shape

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Specification data - Gypsum board partition systems

System performance

Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3

42 Rw (dB).

Fire resistance to BS EN 1364-1 and classification to BS EN 13501-2

EI 60.

Duty rating to BS 5234-2

Severe duty (SD).

Maximum height - cold state

3800 mm.

Thickness

102 mm.

Classification data

System manufacturer

Protektor Group UK Ltd.

Framing

Protektor ECO or MAXI TEC 50 mm C Stud; Protektor ‘ECO’ 52 mm Deep ‘U’ Channel; Protektor ‘ECO’ 52 mm U Track.

Guidance for specification option:

Studs:

  • Protektor ECO or MAXI TEC 50 mm C Stud at 300 mm, 400 mm or 600 mm centres depending on heights.

Head detail:

  • Protektor ‘ECO’ 52 mm Deep ‘U’ Channel x 0.5 mm.

Base detail:

  • Protektor ‘ECO’ 52 mm U Track x 0.5 mm.

Track fixing:

  • Protektor ‘U’ Channels fixed at 400 mm centres into a suitable soffit unless stated otherwise.

Insulation

None.

Fire separation

-

Fire-stopping

-

Manufacturer guidance

As required for penetrations and for base, head and any abutments to masonry, concrete or steelwork.

Insert requirements.

Linings

Two layers 12.5 mm wallboard.

Fasteners

Protektor Drywall Screw’s at 300 mm centres (reduced to 200 mm at external edges).

Joint treatment

-

Manufacturer guidance

All boards to be butt-jointed and either paper-taped or taped and jointed, or scrim taped and skimmed.

Insert requirements.

Finish

-

Manufacturer guidance

Consult manufacturer and insert requirements.

Seamless finishes: using board manufactures finishing products as per their recommendations and Protektor UK products as clause 471 Protektor paper and corner tape or 680 Seamless finishings using Protektor corner, angle and stop bead.

System accessories

Not required.
Protektor ‘ECO’ 70 mm Bracing Strip x 0.6 mm.

Guidance for specification option:

  • Fixing type: Protektor 13 mm Wafer Head Screws.
  • Protektor Flat plate to be installed at all horizontal board joints for fire rated partitions and below deflection heads.

Pattress.

Guidance for specification option:

For plywood installation, Protektor service support plates can be used. These are suitable for either 12 mm, 15 mm or 18 mm.

Height

-

Manufacturer guidance

Build heights.

Consult manufacturer and insert requirements.

  • 600 mm centres: 3400 mm.
  • 400 mm centres: 3600 mm.
  • 300 mm centres: 3800 mm.

Sealing (joints and penetrations)

Intumescent acoustic sealant.

Guidance for specification option:

Twin beads of sealant 6 mm to 8 mm in diameter to base and head track to perimeter junctions with walls, floors, and ceilings and around openings. Use expanding intumescent mastic for all fire rated partitions to head and floor channels below head track and board fillets as required.

Deflection

-

Manufacturer guidance

For up to 25 mm deflection, use board fillets to allow for a 5–10 mm overlap of vertical boarding against board fillets. Boards fillets should have 2 x 6 mm beads of mastic to the substrate, and 2 x beads of mastic to the head track. Please refer to manufacturer for anything above 25 mm.

Insert requirements or omit.

Standards

To BS EN 1264-1, BS 476, BS 5234-2, BS EN ISO 140-3, BS EN 1364 and BS 7634.

Guidance for specification option:

  • BS EN 1264-1 / BS476, Fire resistance tests for non-loadbearing elements - Walls.
  • BS 5234-2, Specification for performance requirements for strength and robustness including methods of test.
  • BS EN ISO 140-3, Acoustics - Measurement of sound insulation in buildings and of building elements. Laboratory measurement of airborne sound insulation of building elements.
  • BS EN 1364, Fire resistance tests for non-loadbearing elements.
  • BS 7634, Galvanised Steel Studs and Channels for Stud and Sheet Partitions.

Sustainability data

Material

Plasterboard
Metal

Similar products from Protektor Group UK

Protektor Maxi-Tec C Stud with Siniat GTEC Standard Board - Partition System