Metsec SFS infill wall with RCM Y-Wall sheathing board, Knauf Rocksilk Rainscreen (external), and Siniat Fire Board (2x12.5) lining.
SFS light gauge galvanised steel structural framing systems provide a fast, light, easily erected alternative
voestalpine Metsec’s metal stud steel framing systems are today specified across countless construction projects, especially for medium-rise commercial, retail, healthcare, educational and municipal applications.
voestalpine Metsec Steel Framing Solution (SFS) is a fast-track metal (galvanised steel) stud panel framing system providing a carrier for insulation, exterior cladding and interior boarding. Cold-rolled galvanized steel sections are typically supplied to site as individual components which are assembled in-situ using screwed connections. Components can be supplied pre-cut to required lengths or cut as needed on site.
A full end-to-end service includes structural technical design and due diligence backed by Professional Indemnity Insurance. In-house manufacturing ensures the highest production quality with capacity to meet the most demanding project schedules.
Metsec SFS infill wall with RCM Y-Wall sheathing board, Knauf Rocksilk Rainscreen (external), and Siniat Fire Board (2x12.5 or 15mm) lining.
Resistance to Fire:
voestalpine Metsec’s fire test data for infill walling is to BS EN 1364‑1: 2015. All test data is based on unique UKAS accredited tests and UKAS accredited scope of testing.
2x12.5mm Fire Board
Fire Performance - Non-Boundary Wall: 60,90,120 Minutes (E)
Fire Performance - Boundary Wall: 60,90,120 Minutes (EI)
MetWALL Perform Warranty
MetWALL Perform, an industry changing warranty giving architects, developers and contractors reassurance when specifying through wall products on voestalpine Metsec steel frame systems.
This is an important addition to voestalpine Metsec’s unique Framing range providing warranted, UKAS tested wall combinations, enabling clients to select the most cost-effective performance design solutions.
Metsec Decarb
voestalpine Metsec’s commitment to sustainable construction is emphasised by the introduction of responsibly sourced steel to our product ranges. Manufactured by processes which minimise carbon output by using state-of-the-art electric arc furnaces powered by renewable energy, rather than the traditional blast furnace which burn fossil fuels, Metsec Decarb promises to make a significant contribution towards reducing the carbon dioxide and carbon footprint of the building project.
System Codes
EXXX-Y1-N090-S22, EXXX-Y1-N100-S22, EXXX-Y1-N120-S22, EXXX-Y1-N150-S22, EXXX-Y1-N180-S22, EXXX-Y1-N200-S22, EXXX-Y1-N210-S22, EXXX-Y1-N240-S22, EXXX-Y1-N270-S22, EXXX-Y1-N300-S22, EXXX-Y1-N350-S22
Finish | Galvanized Guidance for specification option: Steel. |
Material | Steel Plasterboard |
Shape | Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | G10/20 Steel framing system G10/150 Steel framing system |
SKU Code | EXXX-Y1-N090-S22 |
Classification data | |
System performance | Structural design supervision and checking. Design of framing systems generally. Guidance for specification option:
|
Framing members | Cold-formed galvanized steel sections. |
Connections | |
Connection fasteners | Self drilling tek screws. |
Anchors to concrete and masonry | |
Type of anchor | By structural engineer's design. |
Movement joints | Deflection allowance at the top of the wall. |
Insulation | Knauf Rocksilk Rainscreen (external). Guidance for specification option: Insert requirements for external insulation thickness (minimum 75 mm). |
Sheathing board | RCM Y-Wall - 12 mm. |
Framing | Metsec SFS 90 mm stud depth. Guidance for specification option: Typically at 600 mm centres. Manufacturer guidanceSee Insulation if insulation between framing is required. |
Inner layer | Siniat GTEC Fire Board, 12.5 mm. |
Face layer | Siniat GTEC Fire Board, 12.5 mm. |
Fasteners | Drywall screws. |
System accessories | Flatstrap / partition brace. Guidance for specification option: Required behind horizontal board joints. |
Internal face | 120/ 120 minutes (insulation/ integrity). |
External face | 120/ 120 minutes (insulation/ integrity). |
Fire performance | 120 minutes (boundary wall); 120 minutes (non-boundary wall). |
Thermal performance (U-value maximum) | Variable. |
Air tightness | Variable. |
Dimensional constraints | Variable. Guidance for specification option: Consult manufacturer for details based on overall specification. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Material | Steel Plasterboard |
Recyclability | SFS Light Gauge Steel 95-100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 60 % |
| Platform | Compatible | Version |
|---|---|---|
| - | 1 |
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemark™ for BIM Objects
CCPI Product
CCPi - Drylining
CCPI System
CCPI Light Gauge Steel Framing Systems
EPD
Environmental Product Declaration - Decarb SFS
EPD
Environmental Product Declaration EPD - SFS
Metsec SFS Infill wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, and Isover Polterm Max Plus (external)
Metsec SFS infill wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, Knauf Rocksilk RainScreen insulation
Metsec SFS Infill Wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, Rockwool Duoslab insulation
Metsec SFS infill wall with Euroform Easyboard sheathing board, British Gypsum Gyproc plasterboard
Metsec SFS infill wall with Euroform Versaroc sheathing board, British Gypsum Gyproc plasterboard, and Rockwool Duoslab Insulation
Metsec SFS infill wall with Euroform Versaroc sheathing board, Knauf plasterboard, Rockwool Duoslab insulation
Metsec SFS infill wall with Klasse G-board, British Gypsum Gyproc plasterboard, and Knauf Rocksilk Rainscreen (external).
Metsec SFS infill wall with Knauf Windliner sheathing board, Knauf plasterboard, and Knauf Rocksilk RainScreen insulation
Metsec SFS infill wall with OBEX CORTEX 0270FR sheathing board, British Gypsum Gyproc plasterboard, Rockwool Duo Slab insulation
Metsec SFS infill wall with RCM Multipurpose sheathing board, British Gypsum Gyproc plasterboard