Rainscreen cladding system made from Cor-Ten steel, available in a wide range of custom sizes.
Designed for new builds and refurbishment projects. May be installed in horizontal, vertical or diagonal orientations, making it suitable for façades, soffits and interior applications.
The Intalok® Panel System is a contemporary cladding solution engineered for both style and durability. Featuring flat panels with distinctive recessed joints, this system creates a sleek, linear appearance suitable for modern architecture.
Designed with a concealed fixing method, the Interlock Panel System delivers a seamless finish while ensuring excellent wind resistance and long-term stability.
Features and benefits:
Typical system build up:
Finish | Metal Guidance for specification option: Cor-Ten steel. |
Material | Cor-Ten |
Shape | Rectangle |
Length | 6000 mm Guidance for specification option: As standard. Longer lengths available on request. Bespoke |
Width | 300 mm Guidance for specification option: As standard. Narrower widths available on request. Variable width possible, consult manufacturer for guidance. Bespoke |
Warranty description | Manufacturer guidanceNo warranty for Cor-Ten. |
Uniclass | |
CAWS | H2/106 Rigid sheet cladding H20/10 Sheet cladding H92/120 Rainscreen cladding |
Classification data | |
Thermal insulation | Manufacturer guidanceRainscreen cladding does not have any specific requirement with regard to the insulation. Insulation must be structurally self-supporting or supported when installed so that it will not sag and form unvented voids or cause loss of thermal efficiency. An insulation used as a directly supporting substrate must have a minimum compression strength of 50kPa (0.5 kg/cm2) with deformation limited to a maximum of 10%. The insulation must also be dimensionally stable up to 100°C. All insulation must be kept dry and protected prior to metal covering being laid. |
Breather membrane | |
Material | Envirotect Class B-S1,D0 Fire Walling Membrane. Guidance for specification option: May be used when a non-combustible option is required. ISO-Mat Pro® underlay. Guidance for specification option: Recommended for cold vented substrate applications. Manufacturer guidanceThe breather membrane must comply with EN 13859-2 for walls and must also be CE compliant. It is commonly used as a separating underlay, when the metal is being used in conjunction with a metal substrate, to reduce noise. |
Fasteners | Manufacturer guidanceThe breather membrane must be fully supported, lapped and sealed and then further sealed to all surrounding abutments and surface penetrations. |
Secondary support structure | As design. |
Cavity fire barriers | |
Horizontal | To BS 9991. |
Vertical | To BS 9991. |
Cladding panels | |
Material | Cor-Ten. |
Panel joints | Longitudinal joints: Shadow gap with panel closed ends, refer to drawings. |
System accessories | Manufacturer guidanceAll associated flashings to match can be fabricated from coil by Metal Solutions Ltd as per typical details and industry standards. Associated rainwater goods in various sizes and profiles are available in the same material. Consult manufacturer for details and insert requirements. |
System completion | Operation and maintenance manual. |
Fasteners | Stainless screw, SPT-R-S-4.3x20-RS. Guidance for specification option: For fixing to timber. Stainless screw, SX2-D9-4.8x22. Guidance for specification option: For fixing to metal. Stainless screw, DS3-SS-SF-4.8x16. Guidance for specification option: For fixing to metal. Manufacturer guidanceFixings to suit substrate. All associated flashings to perimeters and openings available upon request from Metal Solutions. |
Colour/ Finish | Cor-Ten. |
Size and profile | 300 x 6000 mm. Guidance for specification option: As standard. Other. Guidance for specification option: Narrower and variable widths available on request. Longer lengths on request. |
Weight | 0.9 mm material weight 7.12 kg/m². Guidance for specification option: System weight dependant on panel size and shadow gap. |
Fire classification | Reaction to fire: A1. Guidance for specification option: CWFT – Classified without Further Testing (EU fire protection standards). |
Thickness | 0.9 mm. |
Air and vapour control layer | Manufacturer guidanceVapour barrier membranes must comply with EN 13859-2 for walls and must also be CE compliant. For fully supported metal cladding the vapour barrier membrane must have a minimum water vapour resistance of 4000 MNs/g and comply to BS SO 12572. It also must have a resistance against a supported column of water 2m high for a period of 15 mins to comply with DIN EN 20811. All cladding must have a vapour barrier membrane regardless of being ventilated, unventilated cold or warm in design. The membrane must be positioned behind the insulation and on the warm side of the construction. |
Contains Red List materials | No |
Country of material origin | Europe Guidance for specification option: Sweden/ Finland. |
Country of product manufacture | United Kingdom |
Material | Cor-Ten |
| Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Self-declared | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/kg) Stage:A1–A3 ('Production stage') Normalised unit : 2.17 (kg CO₂ eq/kg) Declared unit : 2.17 | |
Recyclability | 100%. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance17.3% for coils. 18.9% for sheets and slit coils. |