Verified by manufacturer 11 days ago
EXXX-G1-N090-B22 - 90 mm stud
EPD
Certificate type
EPD
Certificate type
BSI Kitemark
Certificate type
BSI Kitemark
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
BSI Kitemark
Certificate type
Metsec SFS infill wall with Klasse G-Board sheathing board, Knauf Rocksilk Rainscreen (external), British Gypsum Gyproc FireLine (2x12.5mm) lining.
SFS infill wall with insulation and plasterboard lining.
Metsec SFS infill wall with Klasse G-Board sheathing board, Knauf Rocksilk Rainscreen (external), British Gypsum Gyproc FireLine (2x12.5mm) lining.
Resistance to Fire
voestalpine Metsec’s fire test data for infill walling is to BS EN 1364‑1:2015. All test data is based on UKAS-accredited tests and UKAS-accredited scope of testing.
Fire Performance - Non-Boundary Wall: 60,90,120 Minutes (E)
Fire Performance - Boundary Wall: 60,90 Minutes (EI)
MetWALL Perform Warranty
MetWALL Perform gives architects, developers and contractors reassurance when specifying through wall products on voestalpine Metsec steel frame systems.
This is an important addition to voestalpine Metsec’s framing range, providing warranted, UKAS-tested wall combinations, enabling clients to select the most cost-effective performance design solutions.
Metsec Decarb
voestalpine Metsec’s commitment to sustainable construction is emphasised by the introduction of responsibly sourced steel to their product ranges. Manufactured by processes which minimise carbon output by using state-of-the-art electric arc furnaces powered by renewable energy, rather than the traditional blast furnace which burn fossil fuels, Metsec Decarb promises to make a significant contribution towards reducing the carbon dioxide and carbon footprint of the building project.
System Codes
EXXX-G1-N090-B22, EXXX-G1-N100-B22, EXXX-G1-N120-B22, EXXX-G1-N150-B22, EXXX-G1-N180-B22, EXXX-G1-N200-B22, EXXX-G1-N210-B22, EXXX-G1-N240-B22, EXXX-G1-N270-B22, EXXX-G1-N300-B22, EXXX-G1-N350-B22
Finish | Galvanized Guidance for specification option: Steel. |
Material | Steel Plasterboard |
Shape | Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | G10/20 Steel framing system G10/150 Steel framing system |
SKU Code | EXXX-G1-N090-B22 |
Product range |
Classification data | |
System performance | Structural design supervision and checking. Design of framing systems generally. Guidance for specification option:
|
Framing members | Cold-formed galvanized steel sections. |
Connections | |
Connection fasteners | Self drilling tek screws. |
Anchors to concrete and masonry | |
Type of anchor | By structural engineers design. |
Movement joints | Deflection allowance at the top of the wall. |
Insulation | Knauf Rocksilk Rainscreen (external). Guidance for specification option: Insert requirements for external insulation, minimum 75 mm. |
Sheathing board | Klasse G-Board - 12 mm. |
Framing | Metsec SFS 90 mm stud depth. Manufacturer guidanceTypically at 600 mm centres. |
Inner layer | British Gypsum Gyproc FireLine, 12.5 mm. |
Face layer | British Gypsum Gyproc FireLine, 12.5 mm. |
Fasteners | Drywall screws. |
System accessories | Flatstrap / partition brace. Guidance for specification option: Required behind horizontal board joints. |
Internal face | 90/ 120 minutes (insulation/ integrity). |
External face | 120/ 120 minutes (insulation/ integrity). |
Fire performance | 90 minutes (boundary wall); 120 minutes (non-boundary wall). |
Thermal performance (U-value maximum) | Variable. |
Air tightness | Variable. |
Dimensional constraints | Variable. Guidance for specification option: Consult manufacturer for details based on overall specification. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Material | Steel Plasterboard |
Recyclability | SFS Light Gauge Steel 95-100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 60 % |
| Platform | Compatible | Version |
|---|---|---|
| - | 1 |
EPD
Environmental Product Declaration EPD - SFS
EPD
Environmental Product Declaration - Decarb SFS
BSI Kitemark
BSI Kitemark™ for BIM Objects
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
UK Conformity Assessed (UKCA)
UKCA Declarations of Performance - Drylining
BSI Kitemark
UKCA Certificate of Conformity of the Factory Production Control
Metsec SFS Infill wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, and Isover Polterm Max Plus (external)
Metsec SFS infill wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, Knauf Rocksilk RainScreen insulation
Metsec SFS Infill Wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, Rockwool Duoslab insulation
Metsec SFS infill wall with Euroform Easyboard sheathing board, British Gypsum Gyproc plasterboard
Metsec SFS infill wall with Euroform Versaroc sheathing board, British Gypsum Gyproc plasterboard, and Rockwool Duoslab Insulation
Metsec SFS infill wall with Euroform Versaroc sheathing board, Knauf plasterboard, Rockwool Duoslab insulation
Metsec SFS infill wall with Knauf Windliner sheathing board, Knauf plasterboard, and Knauf Rocksilk RainScreen insulation
Metsec SFS infill wall with OBEX CORTEX 0270FR sheathing board, British Gypsum Gyproc plasterboard, Rockwool Duo Slab insulation
Metsec SFS infill wall with RCM Multipurpose sheathing board, British Gypsum Gyproc plasterboard
Metsec SFS infill wall with RCM Y-Wall sheathing board, British Gypsum Gyproc FireLine plasterboard, and Knauf Rocksilk Rainscreen (external).